Fill funnel, Lower spray arm, fine filter, and inlet cover, Main conduit – GE PROFILE PDE9900 User Manual

Page 21: Upper spray arm

Advertising
background image

– 21 –

Fill Funnel

The top section of the fi ll funnel separates from the
main body. The fi ll funnel body is held in place by a
nut (located on the inside of the dishwasher). Rotate
the nut counterclockwise to remove the main body.
There is a gasket seal be tween the fi ll funnel and
dish wash er tub. Make certain the gasket is seated
when reinstalling.

Lower

Spray Arm

Nut Hub

Cover Inlet

Hub

Float Dome

Coarse Filter

Fine Filter
Drain Port

Fine Filter

Assembly

Main Conduit

Mounting Screw

Main Conduit

Drain For

Fine Filter

Main Conduit

Tab

Main Conduit

The main conduit supplies water to the middle and
upper spray wash arms.

Removal and Replacement

1. Pull upper rack all the way out.

2. Push the tab on the outer slide cap in and

remove the slide cap.

3. Remove the upper rack.

4. Release the bottom conduit tab.

5. Release 2 center conduit tabs and remove the

main conduit.

Upper Spray Arm

Check the holes in spray wash arm for bits of china,
seeds, and other foreign matter. Also, check the
spray wash arms for rotation.

To remove the upper spray wash arm, remove the
upper rack (see

Middle Spray Arm),

then remove the

screw and upper spray wash arm.

Lower Spray Arm, Fine Filter, and Inlet Cover

Check the holes in spray arm for bits of china, seeds,
and other foreign matter. Also check the spray wash
arms for rotation. If soil is present, clean fi ne fi lter
screen.

The lower spray wash arm can be removed by
gently lifting and rotating it coun ter clock wise.

The nut hub can be removed by rotating it
counterclockwise.

Caution: Use care to avoid breaking the clip on the
hub when removing the main conduit from hub.

Note: When installing the fi ne fi lter, make sure the
drain port of the fi lter is engaged with the drain for
the fi ne fi lter.

Gasket

Nut