Giant HR2527A User Manual

Page 10

Advertising
background image

10

REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030

1. With a 19mm socket wrench, remove the three discharge valve plugs

(34). Inspect the valve plug o-rings (56) for wear, and replace as neces-

sary. Remove the valve spring (18) and valve cone (19) from the manifold

(28). Inspect the parts for wear and replace as necessary.

NOTE:

Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure

proper fit, at the same time protecting the pump's nonmetal parts (elastomers) from cutting and scoring.

2. With a 19mm crescent wrench,

remove the adjusting screw as-

sembly (50, 56, 47, and 59).

Unscrew the adjusting screw

(59) from the adjusting screw

plug (50).

6. Next, remove the three manifold

stud nuts (39) with a 17mm

wrench. Remove the suction

flange (37) and flange o-ring

(38). Inspect the o-ring for wear

and replace as necessary.

5. Inspect the o-rings (56 and 47) for wear and replace as necessary.

Remove the adjusting spring (52), washer (51) and by pass valve ball

(49) from the manifold (28). Inspect the parts for wear and replace

as necessary.

49

51

52

59

47

56

58

4. Inspect the o-ring (36) for wear and replace as necessary.

Remove the kickback valve spring (64), kickback valve cone

(63), and the o-ring (62) from the manifold (28). Inspect and

clean the siphon injector and ball clean parts for wear and

replace as necessary.

3. With a crescent wrench, remove

the injector retainer (76).

36

64

63

62

Advertising