Giant HR2527A User Manual

Page 11

Advertising
background image

11

7. Tap the back of the manifold (28)

with a rubber mallet to dislodge,

and slide off the plungers (10).

Take note of the position of the

discharge port so as to place the

port in the same position during

reassembly.

8. With a 19mm socket wrench, remove the guide plug (54) and o-ring (56)

from the manifold (28). Remove the piston (46), o-ring (47), and backup

rings (48). Using a 7/32" Allen wrench, remove the bypass valve seat

(66). Inspect the parts for wear and replace as necessary.

54

56

48

47

48

46

66

REPAIR INSTRUCTIONS - HR2527A/HR3025/HR3030

NOTE:

Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at

the same time protecting the pump's nonmetal parts (elastomers) from cutting and scoring.

9. Remove the valve cones (19A), valve springs (18), v-sleeves (20) and

pressure rings (22). Inspect for wear and replace as necessary.

Remove the spacer ring (16) and flinger (56) from the plungers (10).

10. If the crankcase oil seals (15)

are to be replaced, they

can be removed by prying

loose with a small screwdriver.

Take care not to make contact

with the plunger (10) and pry

out the oil seals from their

housing.

74 16 22 20 18 19A

Contact Giant Industries for service school information. Phone: (419) 531-4600

11. Reassemble in reverse order.

Fill the crankcase until the

proper amount of oil (see

specifications page 3).

The pump is now ready for

operation.

Advertising
This manual is related to the following products: