Specifications model hr2527a axial pump – Giant HR2527A User Manual

Page 3

Advertising
background image

HR2527A ELECTRIC HORSEPOWER

REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2750 PSI
3450

2.5

1.7

2.6

3.4

4.7

3

Specifications

Model HR2527A

Axial Pump

Volume HR2527A .................................................................................2.5 GPM
Maximum Discharge Pressure .............................................................2750 PSI
Maximum Inlet Pressure ......................................................................Up to 90 PSIG

1

RPM .....................................................................................................3450
Plunger Diameter ..................................................................................16mm
Stroke ....................................................................................................5.3mm (7.1

o

angle)

Crankcase Oil Capacity ........................................................................4.5 fl. oz.
Temperature of Pumped Fluids .............................................................Up to 80

o

F

Inlet Port ...............................................................................................1 x 1/2" NPT
Discharge Ports ....................................................................................3/8" NPT
Shaft Rotation .......................................................................................Clockwise
Weight ...................................................................................................11.7 lbs. (12.7 lbs.)
Width .....................................................................................................6-9/16"
Height ...................................................................................................7-25/32"
Swash Plate Bore .................................................................................3/4" x 3/16" Keyway
Valve Type ............................................................................................Polyamide Plastic

1

A 25 PSIG minimum inlet pressure is required.

HORSEPOWER RATINGS:

The rating shown are the power

requirements for the pump. Gas

engine power outputs must be

approximately twice the pump

power requirements shown above.

We recommend a 1.15 service factor

be specified when selecting an

electric motor as the power source.

To compute specific pump horse-

power requirements, use the Follow-

ing formula:

Electric HP = (GPM X PSI) / 1460

Gas HP = (GPM X PSI) / 1100

HR2527A GAS HORSEPOWER

REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2750 PSI
3450

2.5

2.3

3.4

4.5

6.3

Advertising
This manual is related to the following products: