110v operation – Grizzly G0612 User Manual

Page 10

Advertising
background image

-8-

G0612 6" Jointer

Figure 3. NEMA 5-15 plug and receptacle.

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110V Operation

Grounding

In the event of an electrical short, grounding
reduces the risk of electric shock. This tool is
equipped with a power cord that has a grounding
wire, which must be properly connected to the
grounding prong on the plug; likewise, the outlet
must be properly installed and grounded. All elec-
trical connections must be made in accordance
with local codes and ordinances.

Amperage Draw

The Model G0612 motor draws the following
amps under maximum load:

Maximum Load ...................................... 12 Amps

Circuit Requirements

We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit size given below. Never replace a circuit
breaker with one of higher amperage without con-
sulting a qualified electrician to ensure compli-
ance with wiring codes.

If you are unsure about

the wiring codes in your area or you plan to

connect your machine to a shared circuit, you

may create a fire hazard—consult a qualified

electrician to reduce this risk.

Recommended Circuit Size ...................15 Amps

Plug/Receptacle Type

Included Plug/Receptacle ................ NEMA 5-15

SECTION 2: CIRCUIT REQUIREMENTS

Electrocution or fire could

result if this machine is

not grounded correctly

or if your electrical con-

figuration does not com-

ply with local and state

codes. Ensure compliance

by checking with a quali-

fied electrician!

Extension Cords

We do not recommend the use of extension
cords. Instead, arrange the placement of your
equipment and the installed wiring to eliminate
the need for extension cords.

If you must use an extension cord at 110V with
your machine:

Use at least a 14 gauge cord that does not
exceed 50 feet in length!

The extension cord must also contain a
ground wire and plug pin.

Avoid cords over 50 feet long unless they
have been sized by a qualified electrician.