Step 3, connect ductwork, Step 4, connect electrical, Step 5, install duct covers – GE ZV48R User Manual

Page 13: Step 6, install motor, Installation instructions, Warning, Avertissement, Step 3 connect ductwork, Step 6 install motor

Advertising
background image

13

Installation Instructions

STEP 3 CONNECT DUCTWORK

• Install ductwork, making connections in direction of

airflow as illustrated.

• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints with

duct tape for an airtight seal.

• Use duct tape to seal the

flange connection.
Reach inside the
hood and push
the damper up
to be sure it
moves freely.

STEP 4 CONNECT ELECTRICAL

STEP 5 INSTALL DUCT COVERS

Note:

For easier handling, remove cardboard insert

after film is peeled off.

Remove protective film from duct covers. If more than
one duct cover is used, secure each piece together with
screws provided.
• Place the duct cover(s) on top of the hood.
• From inside the hood, secure the duct cover to the

top with the small Phillips head screws supplied with
the covers.

Verify that power is turned off at the source.

WARNING:

If house wiring is not

2-wire with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.

AVERTISSEMENT –

Si le câblage

de la maison n’est pas du type à deux fils avec un fil de
terre, l’installateur doit fournir un circuit de terre.
Quand les fils de la maison sont en aluminium, il
prendre soin d’utiliser de la pâte antioxidation
approuvée par UL et des connecteurs pour
l’aluminium-cuivre.

• Use wire nuts to connect incoming ground to green,

white to white and black to black.

• Push wires into junction box and replace cover. Be

sure wires are not pinched.

White

Ground

Black

Remove

Junction Box

Cover

Insert Power
Conduit Thru
Strain Relief

and Tighten

Use UL Listed

Wire Nuts

A

B

C

Screw

Duct Tape
Over Seam
and Screw

Air Flow

Duct Tape

Over Transition

STEP 6 INSTALL MOTOR

• From the inside of the hood, slip motor into the

attachment slot on the left.

• Rotate motor upwards until it snaps into the spring

clip on the right.

• Secure the motor to the hood with the machine

screw and lock washer. (Screw is marked with red
or blue paint.)

• Plug connector into the motor.

IMPORTANT: Connector ends
are designed to mate only
one way. Match flat and
round connectors as shown.

Spring

Clip

Outlet

Attachment

Slot

Top

Attachment

Screw

Spring

Clip

Advertising