Installation Instructions

CUT HOLES

Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4

″ extra

toward the front of the cabinet so you can move the
duct freely when installing the hood. It may also ease
installation by cutting the hole 10

1

2

″ instead of 10″.

FOR RECESSED-BOTTOM
CABINETS ONLY

RUN WIRES

Run the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE:

DO NOT turn the power on until

installation is complete.

12

11

13

SCREW IN PARTWAY

Drive a mounting screw (from the hardware packet)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.

FEED IN WIRES

Lift the hood into position and feed the house
wiring through the wiring knockout.

14

15

Wood shims

If the cabinets have front, side or back trim, make

2 wood shims the width of the trim and attach them
to the cabinet bottom recess on both sides. See Step
9 for marking locations.

SECURE HOOD

Slide the hood back against the wall. Tighten
the mounting screws. Be sure the screw heads
are in the narrow neck of the keyhole slot.

Keyhole (4)

Mounting
screw (4)