TROUBLESHOOTING CHECKLIST

If the hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
inadequate, check the following:
❏ Knockouts not removed from hood.
❏ Damper blade not opening.
❏ Reduced airflow because the duct is too small

or the duct length is too long.

❏ The duct is blocked.
❏ Undersized or restrictive wall or roof cap.

REPLACE WIRING COVER

Replace the wiring cover.

15

FOLLOW ELECTRICAL CODE

Complete the electrical wiring according to
National Electrical Code and local codes.
NOTE:

This hood must be permanently grounded.

Connect house wiring (120 VAC) to hood wiring.

CONNECT WIRING

Connect house black to hood black wire, house
white to hood white wire, and house ground to
hood green/yellow wire. Securely tighten the
strain relief clamp onto the house wiring.

19

20

21

22

INSTALL LIGHT BULBS

Purchase and install two PAR20, 50 W maximum
halogen bulbs

. Light bulbs are not included with

the hood.

WARNING:

To reduce the risk of electric

shock, do not connect electrical power to the hood
without both bulbs in place.

18

CONNECT DUCTWORK

TO HOOD

Use duct tape to make joints secure and air tight.

Duct tape

17

REPLACE FILTERS

The installation is complete. Turn on power at
service panel, and test for proper operation.