Problem

Possible Causes

What To Do

Relief valve producing

Pressure buildup caused

This is an unacceptable condition and must be corrected.

popping sound

by thermal expansion

Contact the water supplier or plumbing contractor on how

or draining

to a closed system.

to correct this. do not plug the relief valve outlet.

The heater is beeping

The water heater has not

Fill the tank completely with water. Press ENTER to stop

and the screen says

been filled with water before the alarm and then press POWER when the tank has been

“Attention! Tank not

powering up. Powering up the filled.

filled!”

heater without water will

damage the electric heaters.

The water heater warranty

does not cover damage or

failure resulting from operation

with an empty or partially

empty tank.

The filter light is on.

The filter requires cleaning.

Follow the instructions on how to remove and clean the

A clean filter is necessary for filter on page 13.

effective operation.

The heater is beeping

There is an issue with the

The unit will automatically switch to another available

and the screen says

heat pump system.

mode to ensure you continue to have hot water. Contact

“Heat Pump Failure”

service immediately and give them the codes listed on the

display screen.

The heater is beeping

There is an issue with the

The unit will automatically switch to another available

and the screen says

water heater system.

mode to ensure you continue to have hot water. Contact

“Water Heater Failure”

service immediately and give them the codes listed on the

display screen.

The heater is beeping

There is an issue with the

The heater will need to turn off. Contact service immediately.

and the screen says

water heater that requires

“System Failure”

immediate attention.

The water heater is

Unit is not receiving 240VAC

Turn off power to water heater (generally at the breaker

beeping and the screen

as intended

panel). Then read “Electrical Connections” section of

says, “Wiring to unit

Installation Instructions, see page 17. Then, contact the

incorrect. Must be 240V

installer to verify electrical input to the water heater.

not 120V” or “Heat Pump

Fault”
Hot Water has a rotten

Certain water supplies with

The odor can be reduced or eliminated in most water

egg or sulfur smell

high sulfate content will react heaters by replacing the anode rod with less-active

with the anode rod that is

material rod. In some cases, an added step of

present in all water heaters

chlorinating the water heater and all hot water lines may

for corrosion protection of

be necessary, contact your local water professional or

the tank.

plumber for options and instructions. Call GE at

1.888.4GE.HEWH (1.888.443.4394) to learn how to purchase

this replacement anode rod. A qualified servicer or

plumber should do this replacement. use of a non-GE

approved anode rod, or operating the water heater

without a GE approved anode rod will VOId the warranty.

Unit is not making

If unit is using resistance

Check mode of unit.

normal sounds

elements, it will not make

fan or compressor sounds.

Before you call for service…