model g0528 (mfg. 5/04+)

figure 2. typical 5-15 plug and receptacle.

Grounding Prong is

Longest of the Three

Prongs

Current

Carrying Prongs

Grounded

Outlet

110v Operation

full Load Amperage Draw

this router table is equipped with a 5-15, 110v, 15
amp receptacle, power cord, and power switch.
When selecting a router to use with this router
table, do not use routers that draw more than 15
amps under a full load.

power Supply circuit Requirements

the power supply circuit for the router table
muSt be grounded and rated for the amperage
given below. never replace a circuit breaker on
an existing circuit with one of higher amperage
without consulting a qualified electrician to ensure
compliance with wiring codes.

if you are unsure

about the wiring codes in your area or you

plan to connect your machine to a shared cir-

cuit, consult a qualified electrician.

minimum Circuit Size ............................. 15 amps

This machine MUST have a ground prong in

the plug to help ensure that it is grounded.

DO NOT remove ground prong from plug

to fit into a two-pronged outlet! if the plug

will not fit the outlet, have the proper outlet

installed by a qualified electrician.

Extension cords

We do not recommend using extension cords, but
if you find it absolutely necessary:

use at least a 14 gauge cord that does not
exceed 50 feet in length!

the extension cord must have a ground wire
and plug pin.

a qualified electrician muSt size cords over
50 feet long to prevent motor damage.

SEcTiON 2: ciRcUiT REQUiREMENTS

Serious personal injury could occur if you

connect the machine to power before com-

pleting the setup process. DO NOT connect

the machine to the power until instructed

later in this manual.

Electrocution or fire could

result if machine is not

grounded and installed in

compliance with electrical

codes. compliance MUST

be verified by a qualified

electrician!

power connection Device

this machine comes with a plug, similar to

figure

2, to connect the machine to power.