Troubleshooting

symptom

possible Cause

possible solution

Machine does not
start or a breaker
trips.

1. emergency stop button engaged/at fault.
2. switch disabling key removed.
3. door safety switch disengaged/at fault.
4. thermal overload relay in mag switch

tripped.

5. Break or short in wiring; or loose or

corroded connections.

6. plug or receptacle is corroded or miswired.
7. power supply switched off/has incorrect

voltage.

8. Motor connection wired incorrectly.

9. Contactor has poor contacts or is at fault.

10. Blown fuse/tripped circuit breaker.

11. Motor on/oFF switch at fault.
12. start capacitor has blown.
13. Centrifugal switch at fault.
14. Motor at fault.

1. rotate button to reset/replace button.
2. reinstall switch disabling key.
3. Close door or adjust/replace switch.
4. allow relay/motor to cool. if necessary, press reset

button inside switch.

5. trace/replace broken or corroded wires; fix loose

connections.

6. Correct the wiring.
7. switch power supply on/verify voltage.

8. Wire motor correctly. refer to inside junction box

cover or

page 69 (g0514X), page 70 (g0514X2),

page 71 (g0514X2B), or page 72 (g0514X3).

9. test all legs for power, test field coil, and fix

contacts or replace if at fault.

10. replace/reset fuse or circuit breaker. repair

possible short or circuit overload.

11. replace switch.
12. test/replace if at fault.
13. adjust/replace centrifugal switch.
14. test for shorted windings or bad bearings; repair or

replace.

Main motor chatters
during startup or
during operation.

1. phase converter (if used) wild wire

connected to wrong terminal(g0514X3).

2. power supply has incorrect voltage on one

or more legs.

1. Connect wild wire to the machine power supply

terminal that is not part of the switch coil circuit
(g0514X3).

2. Contact electrician to check incoming voltage.

Machine operates
in reverse.

1. power connections wired out of phase

(g0514X3).

1. swap two power incoming power leads at the motor

(g0514X3).

Review the troubleshooting and procedures in this section if a problem develops with your machine. If you