Startup

18

310892F

WatchDog

Protection System

Pump stops automatically when material pail is empty.

Change Display Units:

To Activate:
1.

Do Startup.

2.

Turn WatchDog switch
ON and WD ON dis-
plays.

EMPTY displays /
flashes and the pump
stops when WatchDog
protection system
detects an empty mate-
rial pail.

3.

Turn WatchDog switch
OFF. Add material or
reprime sprayer. Turn
pump switch OFF and
ON to reset WatchDog
protection system. Turn
WatchDog switch back
ON to continue to moni-
tor material level.

Pressure/Volume:
Press and hold (8 seconds)
DTS button to change pres-
sure units (psi, bar, MPa), to
desired units. Volume units
(GAL, LTRx10) follow pres-
sure units; i.e., psi/GAL and
bar or MPa/LTRx10.

Continue to press DTS but-
ton to cycle from psi to bar to
MPa. Release DTS button to
select units.

WA

C

T

H

D

O

G

/.

/&&

ti6207a

ti6224a

WA

C

T

H

D

O

G

/.

/&&

ti6208a

PSI

BAR

-0A

PSI

SMARTCONTROL

ti6225a