Design Information

Warming Drawer

Advance
Planning

• The drawer may be installed below a

countertop, a cooktop, a single or double
oven and side by side using 2 drawers.

• The warming drawer can be installed below

approved cooktops. Allow 2" min. clearance
from bottom of cooktop burner box to top
of warming drawer cutout. See page 5.

• The warming drawer can be installed below

approved ovens. Allow a 2" min. clearance
between cutouts. Additional clearances may
be required. See page 6.

IMPORTANT – (Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.

Do not use an extension cord or adapter
plug with this appliance. Follow National
electrical codes or prevailing local codes
and ordinances.

This warming drawer must be supplied with
120V, 60Hz, and connected to an individual,
properly grounded branch circuit, and
protected by a 15 or 20 amp circuit breaker
or time delay fuse.

• A properly grounded 3-prong receptacle

should be located within reach of the
drawers’ 56" long power cord.

• Locate the receptacle in an adjacent cabinet.

– within 42" of the right side or,
– within 16" of the left side or,
– A recessed receptacle may be located on

the right side of the cutout, 7" from the
back of the cabinet. In this location, the
excess power cord should be coiled and
taped to the right side of the unit.

• When two warming drawers are installed

side to side, they can operate from the same
receptacle.

IMPORTANT – (Please read carefully)

The power cord of this appliance is equipped
with a 3-prong (grounding) plug that mates
with a standard 3-prong grounding wall
receptacle to minimize the possibility of
electric shock. The customer should have
the wall receptacle and circuit checked by
a qualified electrician to make sure the
receptacle is properly grounded and has the
correct polarity.
• Where a standard 2-prong wall receptacle is

encountered, it is the personal responsibility
and obligation of the customer to have it
replaced with a properly grounded 3-prong
wall receptacle.

Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
DO NOT USE AN EXTENSION CORD.

Grounding
the Appliance

• Electrical power cord is located on the right

side of the warming oven. Locate the outlet
within reach of the 56" long power cord in
an adjacent cabinet, within 42" of the right
side or 16" from the left side of the cutout.
A recessed receptacle can be installed on the
right side of the cutout, 7" max. from the
rear of cabinet.

Drill 1-1/2" Hole
For Power Cord For
Left or Right Side
Outlet Location

Recessed
Receptacle 7"
Max. From Rear
on Right Side.

Rating plate