Option 42: siren time out, Range = 002-254 min (default = 004), Press add – GE 60-883-95R User Manual

Page 23: Press option, Press 4, then 2, Press done, Option 43: house code, Range = a-p (default = a), Press 4, then 3, Exiting programming mode

Advertising
background image

Activity Check

18

Exiting Programming Mode

¾

To exit programming mode and save the changes:

Š Reattach the panel cover.
When you close the cover, the panel reverts to operating mode. The control panel speaker beeps

once.

At any time during programming you can reattach the cover and the changes made to the system

will be saved. When you are ready to continue programming, remove the cover and re-enter an

access code.

Important !

Wait at least 5 seconds before shutting off the CareGard panel after reattaching the cover. This gives

the system time to save the programming changes.

Resetting Memory to Defaults

Note

If Option 8: Phone Lock is

on, Options 3, 4, 6-11 and

Utility Access Code 1 will not

reset to their defaults.

It will be necessary to reset

the clock after resetting

memory.

¾

If it becomes necessary to reset panel programming to the defaults, perform the follow-

ing steps:

1. Turn the ON/OFF switch on the back of the panel to OFF.
2. Open the panel cover.
3. While pressing the Done, 0, and Test buttons turn the ON/OFF switch to ON. Hold the but-

tons until the panel announces “Hello, system X OK.”

4. Release the buttons.

Activity Check

The CareGard system can be set up to report an alarm if no activity is detected within a certain

period of time. Setting Option 41 determines how much time can pass with no activity being

detected before an alarm is generated. See “Option 41: Activity Check” on page 17 for informa-

tion on setting Option 41.

Using CareGard with Activity Check Set

Once the Activity Check option is set the CareGard system must detect activity during the num-

ber of hours selected. The user must press the Status button or activate an activity sensor at least

once during the selected Activity Check time. For example, if the Activity Check is set to 10, at

least every 10 hours the user must press the Status button on the panel or activate an activity sen-

sor. Pressing the Status button resets the timer and the user has another 10 hours to press the Sta-

tus button or activate a sensor within.
Sensors can be set up to detect movement and prevent an Activity Check alarm. For example, a

motion sensor can be placed in the home and as long as the motion sensor detects movement at

Option 42: Siren Time Out

Range = 002-254 Min (Default = 004)

This option determines how long sirens will sound in the event a smoke

alarm or carbon monoxide alarm are activated.

¾

To Add or Delete Siren Time Out:

1. Press Add.
2. Press Option #.
3. Press 4, then 2.
4. Enter the desired Siren Time Out using the

numbered buttons.

5. Press Done.

Option 43: House Code

Range = A-P (Default = A)

The CareGard system can be set up to turn X10 module controlled lights on

and off before an Activity Alarm occurs or during a Medication Reminder.

This option sets the House Code for X10 devices. The House Code pro-

grammed in the panel must match the House Code set on the device. See the

instructions with your X10 module for complete instructions on setting it up.

Important !

To use X10 modules with the CareGard panel you must replace the factory trans-

former with the special X10 transformer (60-972). Complete Installation Instruc-

tions are included with the transformer.

¾

To Add or Delete House Code:

1. Press Add.
2. Press Option #.
3. Press 4, then 3.
4. Enter the desired House Code using the 9

button. Each press of the 9 button will

advance the House Code 1 letter.

5. Press Done.

Advertising