Dust collection air line hook-up – Grizzly G0527 User Manual

Page 18

Advertising
background image

-16-

G0527 18" Wide Belt Sander

To hook up the air line:

1.

Connect the hose from your air compressor
to the air inlet (

Figure 7) on the regulator.

2.

Make sure the red handle on the regulator is
in the open position (parallel with the air
inlet).

3.

Lift the black regulator knob (

Figure 7) and

adjust it until the air pressure gauge reads 75
PSI. Note—

Turn the dial clockwise to

increase the air pressure and counterclock-
wise to lower the air pressure.

4.

Push the regulator knob down until it snaps.

Figure 7. Air inlet located on regulator.

Dust Collection

Air Line Hook-Up

Figure 8. Dust collection hook-up.

An efficient and clean dust collection system is
essential to the proper function of the sander.
Ensuring a healthy work environment is also
dependent upon cleaning and maintaining your
dust collection system.

To hook up the dust collection system:

1.

Install the 4" dust port (

Figure 8) on the

mounting locations at the top of the sanding
unit with the supplied M6-1.0 x 10 phillips
head screws.

2.

Clamp a hose from your dust collection sys-
tem to the dust port.

Air Inlet

Red Handle

(Closed Position)

Black

Regulator

Knob