G0527 18" Wide Belt Sander

The Model G0527 has three motors that are
wired to operate on a 220V single-phase power
source. They will draw the following loads:

Sanding Drum Motor ............................30 Amps
Conveyor Feed Motor ..........................3.8 Amps
Elevation Motor ......................................3 Amps

Use the following guidelines when choosing a cir-
cuit breaker (circuit breakers rated any higher are
not adequate to protect the circuit):

Circuit Breaker ............................40 Amp, 2 Pole

Always check to see if the wires in your circuit are
capable of handling the amperage load from your
machine. If you are unsure, consult a qualified
electrician.

If you operate this machine on any circuit that is
already close to its capacity, it might blow a fuse
or trip a circuit breaker. However, if an unusual
load does not exist and a power failure still
occurs, contact a qualified electrician or our
Service Department at (570) 546-9663.

Circuit Capacity

Figure 1. Locking shut-off lever.

Connection Type

Circuit Breaker

Amperage Draw

Because of the high amperage draw from this
machine, we recommend that you hardwire it
directly to your circuit breaker and install a lock-
ing shut-off lever (

Figure 1) near the machine as

a way to quickly disconnect the power.

SECTION 3: CIRCUIT REQUIREMENTS