Zoneline, Units zoneline units, Rak201 (azc and az series*) access plate cover – GE 49218 User Manual

Page 10

Advertising
background image

10

11

RAK201 (AZC and AZ Series*)

Access Plate Cover

The RAK201 access plate cover is made of heavy-gauge steel
with multiple knockouts for special applications. Will adapt to
service conduit .875" or 1.125"; circuit breaker up to 0 amp or
0 amp receptacle. The RAK201 fits old sub-bases RAK120,
RAK121 and RAK122 for easy replacement of A-B series with
AZC and AZ series.

RAK7022 (AZ Series*—2200, 2500, 2800, 200,

500 and 800 only)

Duct Transition for Replacement

of AZC with Rounded Front AZ Chassis

The RAK7022 duct transition is designed to allow duct installation where
the original chassis was a slope front discharge (AZC/AZR/AZ21/AZ1)
chassis. Using the RAK7022 will allow the existing duct adapter and
extension to be used without requiring the relocation of the hole through
the wall to the adjacent room.

RAK204 (AZ Series*—2200, 2500, 200 and 500 only)

Standard Sub-Base

The RAK204 sub-base is made of heavy-gauge steel to provide support of the
wall case. It has full base enclosure with break-away side channels, simple
connection to wall case, and 4-point leveling legs. The sub-base will adapt to
service conduit, circuit breakers and receptacles up to 0 amps. It may also be
used as a non-electrical sub-base to provide support for the unit.

Circuit

Kit No.

Sub-Base

Ampacity

Chaseway

Power Cord

RAK204U**

Standard

N/A

Not Included

Not Included

RAK204D20

Sub-Base 20/208V

15 & 20

Included

Not Included

RAK204D0

Sub-Base 20/208V

0

Included

Not Included

RAK204E15

Sub-Base 265/277V

15

Included

Not Included

RAK204E20

Sub-Base 265/277V

20

Included

Not Included

RAK204E0

Sub-Base 265/277V

0

Included

Not Included

Power cord and junction box
not included with sub-base.

Chaseway

*

A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 000,

4000, 5000;

AZ Series: Zonelines built after 1992 – Zoneline 2100, 100, 2600, 5100 / Zoneline 2200, 200, 5200 / Zoneline 2500, 500, 5500 / Zoneline 2800, 800, 5800.

Zoneline

®

units

Zoneline units

RAK205CW

(AZ Series*—2200, 2500, 2800, 200, 500, 800, 5200, 5500
and 5800 only)

Chaseway

Chaseway for wiring containment between junction box on
chassis and RAK204U sub-base.

RAK702 (AZ Series*—2100 and 100 only)

Duct Transition for Replacement of

AZC with Sloped Front AZ Chassis

The RAK702 duct transition is designed to allow duct installation
where the original chassis was a slope front discharge (AZC or
AZR) chassis. Using the RAK702 will allow the existing duct
adapter and extension to be used without requiring the
relocation of the hole through the wall to the adjacent room.

RAK7012 (AZ Series*—2200, 2500, 200, 500,

2800 and 800 only)
Duct Adapter for Replacement of

A-B with Rounded Front AZ Chassis

The RAK7012 duct adapter is designed to line up with the duct
extension where the original chassis was a flat-top discharge
A-B Series. Using the RAK7012 will allow the existing duct
extension to be used without requiring the relocation of the hole
through the wall to the adjacent room. Discharge grille, end
plate, and extension mounting hardware must be removed from
old duct adapter and installed on the RAK7012.

8-/8"

6-1/2"

Chaseway

RAK204 (AZ Series*—2800, 800, 5200, 5500 and 5800 only)

Standard Sub-Base

The RAK204 sub-base is made of heavy-gauge steel to provide support
of the wall case. It has full base enclosure with break-away side channels, simple
connection to wall case, and 4-point leveling legs. The sub-base will adapt to
service conduit, circuit breakers and receptacles up to 0 amps. It may also be
used as a non-electrical sub-base to provide support for the unit.

Circuit

Kit No.

Sub-Base

Ampacity

Chaseway

Power Cord

RAK204D15P Sub-Base 20/208V

15

Included

Included

RAK204D20P Sub-Base 20/208V

20

Included

Included

RAK204D0P Sub-Base 20/208V

0

Included

Included

RAK5157/5207/5307

(AZ Series*—2800, 800, 5500 & 5800 only)

265/277-Volt Universal Power Supply Kit

• 9-pin connector with three 7" 12-gauge conductor wires.

Circuit

Kit No.

Volts

Heater Wattage Ampacity

RAK5157

265/277

2.55 kw

15

RAK5207

265/277

.45 kw

20

RAK507

265/277

5.00 kw

0

*

A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 000,

4000, 5000;

AZ Series: Zonelines built after 1992 – Zoneline 2100, 100, 2600, 5100 / Zoneline 2200, 200, 5200 / Zoneline 2500, 500, 5500 / Zoneline 2800/800/5800.

**RAK204U May be used with AZC and AZ 2100, 100, 2600 and 5100.

†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent

connection kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.