Fence stops depth-of-cut scale – Grizzly G0526 User Manual
Page 34
-32-
G0526 6" Jointer
To set the depth-of-cut scale:
1.
Set the outfeed table height as described in
the “Outfeed Table Height” sub-section
.
2.
Place a straightedge across the infeed and
outfeed tables
3.
Adjust the infeed table until it is level with the
outfeed table
.
4.
Adjust the depth-of-cut pointer to read “0”
(
Figure 29
).
Figure 29.
Depth-of-cut pointer
adjusted to “0” position.
The fence stops are adjustable nuts and bolts
that simplify the task of adjusting the fence to 45˚
inward, 90˚, and 45˚ outward (135˚).
To set the 45˚ inward fence stop :
1.
Using a 45˚ square, adjust the fence to the
45˚ inward position
.
2.
Loosen the jam nut shown in
Figure 30
.
3.
Adjust the 45˚ inward fence stop nut until it
makes contact with the back of the fence
bracket
.
4.
Retighten the jam nut loosened in
step 2
.
Figure 30.
45˚ inward fence stop jam nut.
Jam Nut
Fence Stop Nut
Fence Stops
Depth-Of-Cut Scale