440v connection – Grizzly G9962Z User Manual

Page 16

Advertising
background image

-14-

G0445/G0582/G9962Z/9962ZX Wide Belt Sander

440V Connection

To wire the sander to 440V:

1. DISCONNECT THE SANDER FROM THE

POWER SOURCE!

2. Open the electrical box located on the back

of the machine.

3. On the transformer, remove the wire labeled

"

1

" connected to the 220V terminal for your

model of sander, and connect it to the 440V
terminal as shown in

Figure 7.

Figure 7. 440V transformer connection.

5. Wire the sanding belt, conveyor belt, and

table elevation motors as shown on the
diagrams on the inside of each motor wire
cover, or refer to

Motor Wiring on Page 44.

To connect this machine to 440V three-phase,
you must purchase two overload relays. Each
machine model may require unique relays, so
refer to

440V Conversion Relays on Page 65 for

the relay part numbers.

If you do not have three-phase power available for
your wide belt sander, you must install a phase
converter such as a Grizzly Phase Converter.

Note: When using a phase converter, the power
from the manufactured power leg (sometimes
called the wild wire) can fluctuate. Connect the
manufactured power leg to the S terminal to pre-
vent damage to the transformer. The wire from the
S terminal can handle some fluctuation because
it goes directly to the motor. The power going to
the R and T terminals goes to the transformer and
must be consistent to prevent damage.

4. Swap out the applicable thermal relay at the

locations shown in

Figure 8, and set it to the

overload values listed.

Figure 8. Overload relays.

G0445

G0582

G9926ZX

LR3D-216

(12-18A)

Set to:

12.5A

LR3D-076

(1.6-2.5A)

Set to:

1.7A

��

����

���� ����

��

���� ����

G0445

G0582

G9926ZX

Advertising