Table movement, Adjusting feed rate, Notice – Grizzly G9962Z User Manual

Page 24

Advertising
background image

-22-

G0445/G0582/G9962Z/9962ZX Wide Belt Sander

Table Movement

Table height can be adjusted manually or with the

digital key pad and motor (see

Figure 15).

Manual Table Movement: Turn the handwheel
located under the front of the infeed table for
manual table positioning.

Motorized Table Moveme

nt:

Press the TABLE

UP or TABLE DOWN key once for motorized
table positioning in 0.005" (0.1mm) increments.

Numerical Key Pad

:

Push the keys to enter the

sanding depth needed.

Metric or Standard K

ey:

Press and hold the

SET button for 3 seconds to calibrate display at
the current board thickness; or press and hold
key for 10 seconds to toggle the display between
metric and standard measurement.

Table Start

Key:

Push to move table to a preset

sanding depth.

Table Stop

Key:

Push to stop the table move-

ment immediately.

Digital Displa

y:

Shows final table sanding

depth.

The dial attached to the side of the feed belt
gear box (

Figure 16) adjusts the feed rate of the

sander.

Note: Never adjust the feed rate dial unless the
conveyor belt is running, otherwise you can dam-
age the control.

Changing Feed Ra

te:

Turn the dial clockwise to

decrease the feed rate and counterclockwise to
increase it.

Determining Ideal Feed Ra

tes:

Softwoods typi-

cally require a faster feed rate than hardwoods;
however, there is no definitive rule to follow when
determining the best feed rate. As a general rule,
always start with the slowest feed rate and work
your way up. We always recommend testing the
feed rate using scrap wood similar to your work-
piece. Be sure to monitor the amperage meter
when adjusting the feed rate. Decrease the feed
rate if the load amperage level shown on the load
meter is enters the yellow zone or sanding RPM
begins to slow.

Adjusting Feed Rate

Figure 16. Feed rate dial.

Figure 15. Keys for adjusting the table height.

NOTICE

The thickness gauge is pre-calibrated from

the factory; however, correct calibration

should be verified.

Table

UP

Table Down

Metric or

Standard Key

Table

Stop

Table

Start

Digital Display

Numerical

Key Pad

Feed

Rate Dial

Advertising
This manual is related to the following products: