Installing the dryer, Installing the dryer –19, Exhaust direction – GE DVL223 User Manual

Page 13: Gas supply requirements, Exhaust ducting length

Advertising
background image

Replace brass connecting pipe that is not

plastic-coated. Stainless steel or plastic-coated

brass MUST be used.

WARNING:

Never reuse old flexible connectors.

The use of old flexible connectors can cause gas

leaks and personal injury. Always use NEW flexible

connectors when installing a gas appliance.

Installation MUST conform with local codes, or

in the absence of local codes, with the National

Fuel Gas Code, ANSI Z223.1 (latest edition).
The gas supply line should be of 1/2

(1.27 cm)

rigid pipe.
If codes allow, flexible metal tubing may be used

to connect your dryer to the gas supply line. The

tubing MUST be constructed of stainless steel or

plastic-coated brass.

The gas supply line MUST have an individual

shutoff valve.
A 1/8

(0.32 cm) NPT minimum plugged

tapping, accessible for test gauge connection,
MUST

be installed immediately upstream of the

gas supply connection to the dryer.
The dryer and its individual shutoff valve MUST

be disconnected from the gas supply piping

system during any pressure testing of the gas

supply piping system at test pressures in excess

of 1/2 psig (3.45 kPa).
The dryer MUST be isolated from the gas supply

piping system by closing its individual manual

shutoff valve during any pressure testing of the

gas supply piping system at test pressures

equal to or less than 1/2 psig (3.45 kPa).

7

6

5

4

3

2

1

Exhaust Direction

All dryers shipped from the factory are set up for

rear exhausting. However, on ELECTRIC DRYERS,

exhausting can be on the right or left side of the

cabinet or the bottom of the dryer. On GAS DRYERS,

exhausting can be on the right side of the cabinet or

the bottom of the dryer. Directional exhausting can

be accomplished by installing Exhaust Kit, Pub.

No. 14-A018, available through your parts distributor.

Follow the instructions supplied with the kit.

Use only rigid metal ducting inside the dryer cabinet.

Gas Supply Requirements

MAXIMUM LENGTH

of 4“ (10.2 cm) Dia. RIGID METAL DUCT

PREFERRED VENT HOOD TYPE

0

60’ (18.28 m)

48’ (14.63 m)

1

52’ (15.84 m)

40’ (12.19 m)

2

44’ (13.41 m)

32’ (9.75 m)

3

32’ (9.75 m)

24’ (7.31 m)

4

28’ (8.53 m)

16’ (4.87 m)

Exhaust Ducting Length

The exhaust system should be inspected and cleaned

at least once a year with normal usage. The more the

dryer is used, the more often you should check the

exhaust system and vent hood for proper operation.
If roof vents or louvered plenums are used, they must

be equivalent to a 4

dampered wall cap in regard to

resistance to airflow, prevention of back drafts and

maintenance required to prevent clogging.

DO NOT

assemble the duct work with fasteners that

extend into the duct. They will serve as collection

points for lint.

Ductwork which runs through an unheated area or

is near an air conditioning duct should be insulated

to reduce condensation and lint build-up.

4” (10.2 cm)

Louvered

4”

(10.2 cm)

Number of

90° turns

2.5”

(6.35

cm)

MAXIMUM LENGTH

of 4“ (10.2 cm) Dia.

FLEXIBLE METAL DUCT

PREFERRED VENT HOOD TYPE

0

30’ (9.14 m)

18’ (5.49 m)

1

22’ (6.71 m)

14’ (4.27 m)

2

14’ (4.27 m)

10’ (3.05 m)

3

not recommended

4” (10.2 cm)

Louvered

4”

(10.2 cm)

Number of

90° turns

2.5”

(6.35

cm)

CORRECT

INCORRECT

INSTALL MALE FITTINGS IN

CORRECT DIRECTION

Same as
other side

EXHAUST DUCT LOCATING

DIMENSIONS

3-3/4

(9.5 cm)

3-3/4

(9.5 cm)

13-1/2

(34 cm)

4-3/8

(11 cm)

5-7/8

(15 cm)

13