Remove the screws securing the terminal block

access cover and the strain relief mounting

bracket located on the back of the dryer

upper corner.
Install a UL-approved strain relief into the power

cord entry hole of the mounting bracket. Use

a strain relief which attaches to the mounting

bracket with a nut. Finger-tighten the nut only

at this time.
Thread a UL-approved 30A, 240V, 3 #10 AWG

minimum copper conductor power cord through

the strain relief.

Attach the power cord neutral (center wire)

conductor to the silver-colored center terminal

on the terminal block. Tighten the screw

securely.
Attach the remaining two power cord outer

conductors to the outer brass-colored terminals

on the terminal block. Tighten both screws

securely.

WARNING:

Do not make a sharp bend or crimp

wiring/conductor at connections.

Reattach the strain relief mounting bracket to

the back of the dryer with two screws. Tighten

screws securely.
Tighten the fasteners securing the cord restraint

firmly against the power cord.
Tighten the strain relief nut securely so that the

strain relief does not turn.
Reinstall the terminal block access cover.

9

8

7

6

5

4

3

2

1

4-Wire System for Electric Dryers—MUST be used for Mobile Home Installations

Remove the screws securing the terminal block

access cover and the strain relief mounting

bracket located on the back of the dryer

upper corner.
Install a UL-approved strain relief in the entry

hole of the mounting bracket. Use a strain relief

which attaches to the mounting bracket with a

nut. Finger-tighten the nut only at this time.
Remove the green neutral ground wire from

the green ground screw located above the

terminal block.

Thread a UL-approved 30A, 240V, 4 #10 AWG

minimum copper conductor power cord through

the strain relief.
Attach the green power cord ground wire to the

cabinet with the green ground screw.
Attach the white (neutral) power cord conductor

from the power cord and the green ground wire

from the dryer harness to the silver-colored

center terminal on the terminal block. Tighten

the screw securely.

Attach the red and black power cord conductors

to the outer brass-colored terminals on the

terminal block.

WARNING:

Do not make a sharp bend or crimp

wiring/conductor at the connections.

Tighten the fasteners securing the cord

restraint firmly against the power cord.

Tighten the strain relief nut securely so the strain

relief does not turn.
Reinstall the terminal block access cover.

10

9

8

7

6

5

4

3

2

1

3-Wire System for Electric Dryers–DO NOT use for Mobile Home Installations

Green ground screw

Silver terminal

Nut

Tighten nut to
these threads

Power cord

Strain relief

mounting bracket

Green neutral
ground wire

Green ground
screw

Green neutral
ground wire

Red

White

Black

Terminal block

Silver terminal

Green power cord ground wire

Nut

Tighten nut to
these threads

Power cord

Strain

relief

mounting

bracket

Typical 4
conductor
receptacle

Black 240V

White neutral

Red 240V

Green ground

Typical
4 conductor cord

17

Use copper
conductors only.