G0605X/G0606X Extreme Series 12" Table Saw

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

Operation

SECTION 2: CIRCUIT REQUIREMENTS

Amperage Draw

The motor for your machine may draw the follow-
ing amps at maximum load.

G0605X @ 220V .................................. 23 Amps
G0606X @ 220V .................................. 19 Amps
G0606X @ 440V* ................................. 10 Amps

Circuit Requirements

You MUST connect your machine to a grounded
circuit that is rated for the amperage given below.
Never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes.

If you are unsure about the

wiring codes in your area or you plan to con-

nect your machine to a shared circuit, consult

a qualified electrician.

G0605X @ 220V .................................. 30 Amps
G0605X @ 220V .................................. 30 Amps
G0606X @ 440V* ................................. 15 Amps

*

To run on 440V, you must rewire the motor,

switch the transformer fuse from 220V to

440V, and change the thermal overload relay

from 22 to 11 Amps. Refer to the wiring dia-

gram on Page 59 for wiring details.

Plug Type

The cord set enclosed does not have a plug as
the style of plug you will require depends upon
the type of service you currently have or plan to
install. We recommend using the following plugs
for your machine on a dedicated circuit only (see
Figures 2–4 for examples):

G0605X @220V Single-Phase .................. L6-30
G0606X @220V 3-Phase .........................L15-30
G0606X @440V 3-Phs ... Power Shut-Off Switch

Figure 2. NEMA L6-30 plug and receptacle.

Figure 3. NEMA L15-30 plug and receptacle.