17

FUNCTION TESTS

1 Select a test area that is firm, level and free of

obstruction.

At the Ground Controls

2 Turn the key switch to ground control.

3 Pull out the red Emergency Stop button to the

on position.

Result: The beacon (if equipped) should flash.

4 Start the engine. See Operating Instructions

section.

Test the Emergency Stop

5 Push in the red Emergency Stop button to the

off position.

Result: The engine should turn off and all

functions should not operate.

6 Pull out the red Emergency Stop button to

the on position and restart the engine.

Test the Machine Functions

7 Do not hold the function enable

switch to either side. Attempt to
activate each boom and platform
function toggle switch.

Result: All boom and platform functions should

not operate.

8 Hold the function enable switch to either side

and activate each boom and platform function
toggle switch.

Result: All boom and platform functions should

operate through a full cycle. The descent alarm
(if equipped) should sound while the boom is
lowering.

Test the Tilt Sensor

9 Pull out the platform red Emergency Stop button

to the on position. Turn the key switch to
platform control.

10 Open the ground control side turntable cover and

locate the tilt sensor.

11 Press down one side of the tilt

sensor.

Result: The alarm, located in

the platform, should sound.

Test Auxiliary Controls

12 Turn the key switch to ground control and shut

the engine off.

13 Pull out the red Emergency Stop button to the

on position.

14 Simultaneously hold the

auxiliary power switch on and
activate each boom function
toggle switch.

Note: To conserve battery power, test each
function through a partial cycle.

Result: All boom functions should operate.