Drive Enable

Light on indicates that the boom
has moved just past either non-
steer wheel and the drive
function has been interrupted.

To drive, hold the drive enable switch to either side
and slowly move the drive control handle off center.

Be aware that the machine may move in the
opposite direction that the drive and steer controls
are moved.

Always use the color-coded direction arrows on the
platform controls and the drive chassis to identify
the direction the machine will travel.

Drive Speed Select

·

Machine on incline symbol: Low range operation

for inclines

·

Machine on level surface symbol: High range

operation for maximum drive speed

Engine Idle Select (rpm)

Select the engine idle (rpm) using the symbols on
the control panel.

·

Rabbit and foot switch symbol: foot switch

activated high idle

·

Turtle symbol: low idle

·

Rabbit symbol: high idle

Generator (if equipped)

To start the generator, move the generator toggle
switch to the on position.

Plug a power tool into the power to platform GFCI
outlet.

To turn off the generator, move the generator toggle
switch to the off position.

Note: Machine functions will not operate while the
generator is running and the foot switch is not
pressed down. When the foot switch is pressed
down, the generator will turn off and the machine
functions will operate.