Incorrect positions – Gas-Fired Products PTS Series 100 User Manual

Page 30

Advertising
background image

Form #43343530

July 08

–29–

* Available as Accessories

KEY DIMENSIONS AND COMPONENTS OF THE GAS CONNECTIONS

14 to 17”

(36 to 43cm)

Approved

Flexible Connector

*Second Stage Regulator with

Vent Leak Limiter to reduce the

Supply Pressure below 14” W.C.

Gas Pressure

= 2 PSIG
Gas Supply

Piping

Sediment Trap

(Drip Leg)

*Manual Gas

Shut Off Valve

Burner Movement

2” (5cm) Max.

Displacement

END VIEW

RECOMMENDED GAS CONNECTION POSITIONS WITH 36” FLEXIBLE GAS HOSE

Adaptor 1/2” NPT female

Gas pipe work must not restrict

opening of hinged service doors.

7 5/8”

Alternate Positions

SIDE VIEW

Adaptor 1/2” NPT male

Burner Movement

DO NOT install gas connector

vertically if fresh air is to be

connected.

Minimum 1” (25cm)

3 7/8” (10cm)


Certified connectors are recommended to be installed as shown, in one plane, and without sharp bends, kinks or
twists.


INCORRECT POSITIONS

Movement

WRONG

Movement

WRONG

Movement

WRONG

Movement

WRONG



Advertising