14 rv generator service interval – Generac 004700-0 User Manual

Page 18

Advertising
background image

16 Generac

®

Power Systems, Inc.

2. When valve clearance is correct, hold the pivot

ball stud with the allen wrench and tighten the
rocker arm jam nut with a crows foot. Tighten the
jam nut to 65-85 inch-pounds torque. After tight-
ening the jam nut, recheck valve clearance to
make sure it did not change (Figure 3.8).

Figure 3.8 — Tightening Jam Nut

3.14 RV GENERATOR SERVICE

INTERVAL

Quietpact 40
50 Hours ................................Clean Spark Arrestor
100 Hours ..........................Change Engine Oil/filter
100 Hours ..................................Clean Air Pre-filter
100 Hours ................................Inspect Spark Plugs
250 Hours ............Replace Paper Air Filter Element
400 Hours ..................................Replace Fuel Filter
500 Hours................................Replace Spark Plugs
1st 50 Hours-then

every 500 Hrs. ..........................Adjust Valve Lash

Section 3 – Maintenance

QUIETPACT 40G Recreational Vehicle Generator