Gas valve coil assembly, Lp conversion – GE DCVH515 User Manual

Page 36

Advertising
background image

– 36 –

Gas Valve Coil Assembly

The gas valve coil assembly is located on top of
the gas valve in front of the combustion chamber
opening. The assembly consists of a double coil
(saftey and booster coils combined) and a single
main coil. The coil assemblies can be replaced
separately.

Gas valve coil assembly resistance values:

Saftey coil terminals - 1350

Booster coil terminals - 550

Main coil terminals - 1300

Main Coil

Booster Coil

Safety Coil

To remove the coils:

Remove the top, control, and front panels. (See

Top Panel, Control Panel

and

Front Panel

.)

Remove the drum. (See

Drum

.)

Disconnect the wire harness from both coils.

1.

2.

3.

(Continued Next Page)

Bracket

Locator Pins

Lift the bracket vertically. Lift coils to remove.

Note: Upon reassembly, ensure the locator pins are
inserted into the holes provided in the coil bracket.

5.

LP Conversion

The gas dryer comes equipped for natural gas.
The dryer can be converted to LP gas by using
the conversion kit WE25X217. Should you need to
convert an LP dryer back to natural gas and the
original parts are missing, a WE25X218 kit contains
all the parts required to convert back to natural gas.

Remove the 2 Phillips-head screws that attach

the coil bracket to the valve body.

4.