Frequently asked questions 22, Frequently asked questions – Miele KWT4154UG1 User Manual

Page 22

Advertising
background image

With the aid of the following guide minor problems can be corrected without a ser-
vice call.

Repairs should only be carried out by a qualified and trained person in strict
accordance with local and national safety regulations. Unauthorized repairs
could cause personal injury or machine damage and may void the warranty.

What if the appliance does not get cold?

Possible fault

Solution

The machine is not turned on.

Check whether the appliance is
switched on. The display must be lit up.

The machine is not plugged in.

Check that the plug is correctly
inserted in the power outlet.

Check that the fuse has not tripped.

Reset the circuit breaker.

What if the compressor kicks on very frequently and for too long?

The ventilation slits are covered or
dusty.

Clean with a vacuum or brush.

The door has been opened too
frequently.

Once the appliance returns to the set
temperature the compressor will turn
off.

The door is not closed.

Check that the door has been closed
properly.

What if the alarm sounds and the temperature display flashes?

The appliance door has been opened
for more than 60 seconds.

Close the door.

The appliance door has been opened
too frequently.

One of these conditions has caused the
temperature in the appliance to
become too warm or cold.
Once the alarm condition has been
corrected, the temperature display will
light up continuously and the alarm will
turn off.

The ventilation slits are covered.

A power failure has occurred.

Frequently asked questions

22