9. arc controls, 10. postflow time control – Miller Electric SYNCROWAVE 250 TM-353E User Manual

Page 22

Advertising
background image

TM-353 Page 18

Syncrowave 250

4-9.

Arc Controls

1

Arc Control (Dig)

For AC And DC SMAW Welding

When set at 0, short-circuit amper-
age at low arc voltage is the same
as normal welding amperage.

When setting is increased, short-
circuit amperage at low arc voltage
increases.

Set at 0 for GTAW welding.

2

Arc Control Switch

Place switch in the ON position to
turn on arc control circuitry. When
switch is in the OFF position, no ad-
ditional amperage is available at
low arc voltages. Place switch in
the OFF position while performing
Gas Tungsten Arc Welding
(GTAW).

Application:

Control helps arc starting or making
vertical or overhead welds by in-
creasing amperage at low arc volt-
age, and reduces electrode sticking
while welding.

2

1

4-10. Postflow Time Control

1

Postflow Time Control

Use control to set length of time
(0–70 seconds) gas flows after
welding stops. It is important to set
enough time to allow gas to flow un-
til after the tungsten and weld
puddle has cooled down.

Application:

Postflow is required to cool tung-
sten and weld, and to prevent con-
tamination of tungsten and weld. In-
crease postflow time if tungsten or
weld are dark in appearance.

1