Miller Electric SYNCROWAVE 250 TM-353E User Manual

Page 38

Advertising
background image

TM-353 Page 34

Syncrowave 250

6-7.

Remote 14 Filter Board PC2 Test Point Values (Use With Section 6-2 And Section 6-6)

PC2 Voltage Readings

a) Tolerance –

±

10% unless

specified

b) Reference – to circuit common

(lead 42) unless noted

Receptacle

Pin

Value

RC1

A

24 volts ac

B

Contact closure to A completes 24 volts ac contactor control circuit

C

Command reference; 0 to +10 volts dc output to remote control

D

Remote control circuit common

E

0 to +10 volts dc input command signal from remote control

K

Chassis common

RC2

1

Command reference; 0 to +10 volts dc output to remote control

3

Contact closure to A completes 24 volts ac contactor control circuit

4

Remote control circuit common

5

0 to +10 volts dc input command signal from remote control

6

24 volts ac

RC3

1

Chassis common

Advertising