6-7.
Remote 14 Filter Board PC2 Test Point Values (Use With Section 6-2 And Section 6-6)
PC2 Voltage Readings
a) Tolerance –
±
10% unless
specified
b) Reference – to circuit common
(lead 42) unless noted
Receptacle
Pin
Value
RC1
A
24 volts ac
B
Contact closure to A completes 24 volts ac contactor control circuit
C
Command reference; 0 to +10 volts dc output to remote control
D
Remote control circuit common
E
0 to +10 volts dc input command signal from remote control
K
Chassis common
RC2
1
Command reference; 0 to +10 volts dc output to remote control
3
Contact closure to A completes 24 volts ac contactor control circuit
4
Remote control circuit common
5
0 to +10 volts dc input command signal from remote control
6
24 volts ac
RC3
1
Chassis common
Advertising