Miller Electric SYNCROWAVE 250 TM-353E User Manual

Page 31

Advertising
background image

TM-353 Page 27

Syncrowave 250

SC-188 161

Test Equipment Needed:

V24

V22

V21

R3

R2

V20

A A

A

A

R1

V25

Resistance Values

a)

Tolerance –

±

10% unless specified

b)

Turn Off unit and disconnect input
power before checking resistance

R1

All values for T1, Z1, and T3 are less
than 1 ohm

R2

5.3 ohms

R3

6.1 K ohms

Voltage Readings

a)

Tolerance –

±

10% unless

specified

b)

Reference

– to circuit

common (lead 42) unless
noted

c)

Wiring Diagram – see
Section 10

V1

230 volts ac

V2

77 volts ac

V3

82.5 volts ac

V4

57 volts ac

V5, V6

115 volts ac

V7

24 volts ac

V8, V9

18 volts ac

V10

10 volts ac

V11

80 volts dc

V12. V13, V14

115 volts ac

V15, V16, V17

24 volts ac

V18

115 volts ac with S2
in Start or Con-
tinuous

V19

0 to +10 volts dc
with contactor on

V20, V21

24 volts dc

V22

0-80 volts dc (rec-
tified arc voltage)

V23

maximum 80 volts
ac/dc

V24

24 volts dc

V25

16.5 millivolts dc
per 1 ampere of
weld output

CR1 energizes

when open-circuit voltage

is present; denergizes

when an

arc is struck

See Figure 10-1 for

HD1 location

No calibration available

for voltmeter V1

R1

V23, B,
C, D, E

See Section 6-3

for waveforms

B, C, D, E

See also

Sections 6-4 and 6-5

for PC1 data

CR5 energizes when

contactor is on

See Section 6-8
for ammeter A1

calibration

V19

V18

See Section 6-3
for waveform A

Advertising