Miller Electric CV-2 User Manual

Page 14

Advertising
background image

OM-880 Page 10

SA-112 730

Welding

Generator

Connection To

CV-2 5-Socket

Amphenol

Receptacle RC3

Work

Electrode Holder

Optional Remote

Contactor And

Amperage Control

Figure 3-8. Connection Diagram For Remote Control Using 5-Socket Amphenol Receptacle RC3

SA-112 732

Welding

Generator

Gas Supply With

Flowmeter And

Regulator

Gas Hose

Electrode Cable

Connection To CV-2

14-Socket Amphenol

Receptacle RC4

Spoolmatic 3

Gun/Feeder

Work

Figure 3-9. Connection Diagram For Spoolmatic 3 Using 14-Socket Amphenol Receptacle RC4

SA-112 735

Welding

Generator

Gas Supply With

Flowmeter And

Regulator

Gas Hose

Electrode Cable

Connection To CV-2

14-Socket Amphenol

Receptacle RC4 - Use

Work

14-Pin To 14-Pin

Interconnecting Cord

Wire Drive

Assembly

3 ft. (914 mm)

Long Pigtail

With Amphenol

Welding

Gun

S-32 Type Wire Feeder

With 12VDC Optional

Shielding Gas Valve,

Remote Contactor,

And Voltage Control

Figure 3-10. Connection Diagram For S-32P Type Wire Feeders Using

14-Socket Amphenol Receptacle RC4