Table 6-3. Troubleshooting

TROUBLE

PROBABLE

REMEDY

Wire feeder inoperative.

Circuit breaker CB5 or CB6 open.

Reset CB5 or CB6 according to
Section 6-2.

No remote control of con-

OUTPUT/CONTACTOR switch S10

Place S10 in the REMOTE position

tactor; open-circuit voltage in the ON position.

(see Section 4-3).

present all the time when
engine is running.

No contactor control; no

CV-2 not correctly installed if done as

Review Section 3 and check all

weld output; no open-

a field kit.

connections.

circuit voltage.

Incorrect or poor connections to

Check and secure connections (see

REMOTE-5 receptacle RC3 or

Sections 3-2 and 3-3).

REMOTE-14 receptacle RC4.

Remote Contactor Control device.

Check and repair or replace remote
device as necessary.

Contactor control circuit board PC3.

Replace PC3 according to Section 6-3.

Improper current or volt-

Remote current and/or voltage control

Use only one CV-2 receptacle for

age level adjustment with

device connected at both receptacles.

remote current or voltage control.

remote control device.

No control of voltage;

CV-2 not correctly installed if done as a

Review Section 3 and check all

maximum or very low or

field kit (cables 19 and 30 from rectifier

connections, especially cables 19 and

no open-circuit voltage

SR3 reversed to Selector Switch cables). 30.

present.

Incorrect or poor connections to

Check and secure connections (see

REMOTE-5 receptacle RC3 or

Sections 3-2 and 3-3).

REMOTE-14 receptacle RC4.

CV/CC switch S12 in CC position.

Place S12 in the CV position (see
Section 4-1).

Remote Voltage Control device.

Check and repair or replace remote
device as necessary.

Voltage control circuit board PC4.

Replace PC4 according to Section 6-3.