Cc cv, Panel, Current control remote – Miller Electric CV-2 User Manual

Page 17

Advertising
background image

OM-880 Page 13

SECTION 4 – OPERATOR CONTROLS

SC-111 216-A

Circuit

Breaker CB5

Remote-14

Receptacle RC4

Circuit Breaker CB6

Output/Contactor

Switch S10

Current Control

Switch S11

Constant Voltage (CV)/

Constant Current(CC)

Switch S12

Prepunched Hole

For Securing

Key Chain

Remote-5

Receptacle RC3

Receptacle

Dust Cups

AC/DC Selector

Switch S1

CV-2 Control

Panel

Figure 4-1. CV-2 Panel Components

4-1.

CONSTANT VOLTAGE (CV)/CONSTANT
CURRENT (CC) SWITCH (Figure 4-1)

CC

CV

Placing this switch in the CC position causes the weld-
ing generator to provide weld output for processes re-
quiring a constant current output.

Placing this switch in the CV position causes the welding
generator to provide weld output for processes requiring
a constant voltage output.

IMPORTANT: When using the CV mode, place the AM-
PERE RANGES switch on the welding generator in the
maximum amperage range position.

4-2.

CURRENT CONTROL SWITCH (Figure 4-1)

PANEL

A
V

CURRENT
CONTROL

REMOTE

WARNING: ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Do not touch weld output terminals when
contactor is energized.

Do not touch welding wire or electrode and
work clamp at the same time.

If remote current or voltage control is desired, make
connections to either the REMOTE-5 or REMOTE-14
receptacle as instructed in Section 3-2 or 3-3. Place the
CURRENT CONTROL switch in the REMOTE position.

Advertising