6. connecting to weld output terminals, 7. selecting weld cable sizes – Miller Electric 185 User Manual

Page 24

Advertising
background image

.

Complete Parts List available at www.MillerWelds.com

OM-4415 Page 20

5-6. Connecting To Weld Output Terminals

803 596−B / 803 778-A

1

Positive (+) Weld Output

Terminal

2

Negative (−) Weld Output

Terminal

For Direct Current Electrode Posi-

tive (DCEP), connect work cable to

Negative (−) terminal and electrode

holder to Positive (+) terminal.
For Direct Current Electrode nega-

tive (DCEN), reverse cable con-

nections.

Tools Needed:

3/4 in

6

4

5

Do not place

anything between

Correct Installation

Incorrect Installation

3

weld cable terminal

and copper bar.

1

2

Failure to properly connect weld

cables may cause excessive

heat and start a fire, or damage

your machine.
3

Weld Output Terminal

4

Supplied Weld Output

Terminal Nut

5

Weld Cable Terminal

6

Copper Bar

Remove supplied nut from weld

output terminal. Slide weld cable

terminal onto weld output terminal

and secure with nut so that weld

cable terminal is tight against cop-

per bar. Do not place anything

between weld cable terminal

and copper bar. Make sure that

the surfaces of the weld cable

terminal and copper bar are

clean.

5-7. Selecting Weld Cable Sizes*

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

Not Exceeding***

100 ft (30 m) or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Weld O tp t

Welding

Amperes

10 − 60%

Duty

Cycle

60 − 100%

Duty

Cycle

10 − 100% Duty Cycle

Weld Output

Terminals

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

Stop engine before

connecting to weld

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

3/0 (95)

connecting to weld

output terminals.

Do not use worn dam-

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 4/0 (120)

Do not use worn, dam-

aged, undersized, or

poorly spliced cables.

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 2/0

(2x70)

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

*

This chart is a general guideline and may not suit all applications. If cables overheat, use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

( ) = mm

2

for metric use

S-0007-F

***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.