OM-4415 Page 23

6-2. Description Of Controls (Standard Models) (See Section 6-1)

1

Engine Switch

Use switch to control ignition circuit. Turn

switch to On position when starting engine.

Turn switch to Off position to stop engine. En-

gine cannot be started with switch in the Off

position.
Engine stops if oil level is too low. Engine can-

not be restarted until sufficient oil is added.
2

Starter Handle

3

Choke Control

Use control to change engine air/fuel mix.

Move control to far right if starting a cold en-

gine. Move control to far left if starting a warm

engine.
To Start:

D Open fuel valve (see Section 5-3).
D Turn Engine switch to On.

D Set choke.
D Pull starter handle. Open choke as en-

gine warms.

To Stop:

D Turn Engine switch to Off.

.

Always close fuel valve after stopping
unit. Moving unit with fuel valve open may

cause carburetor flooding and make

starting difficult.

4

Welding Range Table

Use table to determine correct weld amper-

age based on electrode size, type, and mate-

rial thickness.

5

Weld Output Control

.

Set control at maximum for full generator

power output at AC receptacles

Use control to select weld amperage. Control

may be adjusted while welding.
To Set Weld Output Control: Use table to

determine correct size electrode for weld am-

perage. Select electrode type and set control

to corresponding amperage range on name-

plate. Adjust control to obtain desired weld

performance.
EXAMPLE:
Electrode Diameter: 1/8
Electrode Type: E-6013
Current Control Setting: 90 − 120 A

If the engine does not start, let

engine come to a complete stop

before attempting restart.

Notes