148

PENT/ATCA−717

Table 35:

Version Register

Bit

Description

Default

Access

7..0

FPGA version

FD

16

a

(at the time of

writing this guide)

r

Access Control Register

This register determines the current owner of the following interfaces:

S Clock synchronisation building block interface

S Ethernet switch management interface

S SPROM update interface
The current owner of each interface is either the IPMC or the host CPU.

a

Only the current owner has write access to the corresponding registers. The
non−proprietor has only read access.

a

If the non−proprietor wants to become owner, it has to request ownership from the
current owner. The current owner then has to grant ownership by inverting the bit
corresponding to the interface.

a

Table 36:

Access Control Register

Bit

Description

Default

Access

0

Indicates the current owner of the clock
synchronisation building block interface
0: Host

a

1: IPMC

0

2

r/w

1

Indicates current owner of Ethernet switch
management interface
0: Host
1: IPMC

1

2

r/w

2

Indicates the current owner of the SPROM
update interface
0: Host
1: IPMC

0

2

r/w

7..3

Reserved

00000

2

r