Controls, Indicators, and Connectors

On−Board Connectors

66

PENT/ATCA−717

On the PMC sites 1 and 4, two Ethernet ports (signals named ETH*_) are routed to the
on−board switch. On the PMC sites 2 and 3, only one port is routed to the on−board
switch. The following two figures show the connector pinouts.

aaa

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

41

43

45

47

49

51

53

55

57

59

61

63

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

42

44

46

48

50

52

54

56

58

60

62

64

n.c.

n.c.

n.c.

n.c.

n.c.

GND

ETHB_DC+

ETHB_DC−

GND

ETHB_DD+

ETHB_DD−

n.c.

PMC_IO_26

PMC_IO_28

CLK8_A or PMC_IO_30

n.c.

PMC_IO_34

PMC_IO_36

PMC_IO_38

PMC_IO_40

PMC_IO_42

PMC_IO_44

PMC_IO_46

PMC_IO_48

n.c.

PMC_IO_52

PMC_IO_54

n.c.

PMC_IO_58

PMC_IO_60

PMC_IO_62

PMC_IO_64

n.c.

n.c.

n.c.

n.c.

n.c.

GND

ETHB_DA+

ETHB_DA−

GND

ETHB_DB+

ETHB_DB−

NETREF

PMC_IO_25

n.c.

PMC_IO_29

CLK8_B or PMC_IO_31

PMC_IO_33

PMC_IO_35

PMC_IO_37

PMC_IO_39

PMC_IO_41

PMC_IO_43

PMC_IO_45

PMC_IO_47

PMC_IO_49

PMC_IO_51

PMC_IO_53

PMC_IO_55

PMC_IO_57

PMC_IO_59

PMC_IO_61

PMC_IO_63

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

}

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

{

Diff. Pair

Figure 13:

PMC Sites 1 and 4 − Pn4 Connector Pinout