Lamp replacement, En - 26, Interval of lamp replacement – MITSUBISHI ELECTRIC XD450U User Manual

Page 26

Advertising
background image

EN - 26

Lamp replacement

9. Tighten up the screw (a) using a

Phillips screwdriver (+) to secure

the lamp cover.

Reset of the lamp operation time

Plug in the power cord, turn on the

lamp, and reset the lamp operation

time by keep pressing the , , and POWER buttons

on the control panel at the same time about three sec-

onds.
Important:

• Unless these three buttons are pressed at the same

time, the lamp operation time isn't reset.

• Make sure that the STATUS indicator is lit twice and

the lamp operation time is reset successfully.

• The projector doesn't turn on if the lamp cover isn't

attached securely.

• Be sure to reset the lamp operation time whenever

you replace the lamp.

• Do not reset the lamp operation time unless you

replace the lamp.

Caution:

• The lamp is fragile. If it is broken, be careful not to

cut yourself with glass fragments.

• Contact your dealer for a new lamp.

Interval of lamp replacement

The recommended interval of lamp replacement is about

5000 hours*

1,

*

2

of consecutive use. Such interval differs

depending on the operating environment and may be

shorter than 5000 hours*

1,

*

2

. Decrease in luminescence

and/or color brightness indicates that the lamp needs

to be replaced. When the lamp operation time exceeds

3750 hours*

1

, the indicator will blink alternately between

green and red (while the lamp is lit; when the lamp is

not lit, the indicator will be blink red only) and the lamp

replacement message will appear on the screen for one

minute every time the lamp is turned on. When the lamp

has been used for about 4750 hours*

1

, the replacement

message (LAMP EXCHANGE) will appear on the screen

for one minute every 25 hours*

1

thereafter.

When the lamp operation time exceeds 5000 hours*

1

*

2

,

the projector automatically shuts off and can't be used

until the lamp is replaced and the lamp operation time

is reset.
For XD450U only

*

1

When LAMP MODE of the INSTALLATION menu is

set to LOW. When it is set to STANDARD, this dura-

tion will be shortened.

*

2

When LAMP MODE is set to STANDARD, this dura-

tion will be shortened to 2000 hours.

Caution:

• This projector uses a lamp that contains mercury.

Disposal of the lamp or the projector with the lamp

may be regulated due to environmental consider-

ations. For disposal or recycling information, please

contact your local authorities or the Electronic Indus-

tries Alliance: www.eiae.org. (For US only).

(a)

(b)

(c)

When the lamp no longer functions, replace it with a

new one.
Caution:

• Do not remove the lamp immediately after using the

projector. You may get burned because the lamp is

very hot after use.

• Before replacing the lamp, press the POWER button

to turn off the lamp and wait for two minutes for the

lamp to cool down. Unplug the power cord from the

wall outlet and wait one hour for the lamp to cool

down completely.

• Do not remove the lamp except for replacement.

Careless handling can cause injury or fire.

• Do not touch the lamp directly. It may break and

cause injury or burn.

• Be sure not to drop the lamp lid screw into the

projector. Also be sure not to put metal or any

flammable objects inside because it may cause fire

or electric shock. If any objects should fall inside,

unplug and contact your dealer.

• Install the lamp securely to prevent failure and fire.

• If the lamp should break, small glass fragments may

fall out through the grilles and some may remain

inside of the projector or the lamp box. When taking

the lamp box out, be sure to turn over the projector

and hold the handle of the lamp box to avoid injury

due to the glass fragments.

• If the lamp should break, never shake the lamp box

or hold it in front of your face after removing it. The

glass fragments may fall out and cause injury to your

eyes.

• When placing the projector upside down to replace

the lamp or conduct maintenance, ensure that the

projector is securely placed before working with it.

1. Reverse the projector gently.
2. Loosen the screw (a) using a

Phillips screwdriver (+), and

remove the lamp cover (b).

3. Loosen the screws (c) using a

Phillips screwdriver (+).

4. Pull up the handle.
5. Pull out the lamp box by the handle

while holding the projector.

• Pull the lamp box out of the

projector slowly. If it is pulled

out quickly, the lamp may break

scattering glass fragments.

• Do not spill liquid on the removed

lamp box or do not place it near

any flammable object or where

children can reach to prevent

injury or fire.

6. Load a new lamp box securely into the

projector in the right orientation.

7. Put the handle back to the original posi-

tion.

• Make sure that the handle is locked.

8. Tighten up the screws (c) using a Phillips

screwdriver (+).

(c)

Advertising