6 trouble shooting, 1 trouble criterion of main parts, Normal abnormal(faulty) – MITSUBISHI ELECTRIC MR-455R-W-A(NZ) User Manual

Page 15: Rear side of the frame, The machine, Rear side of the machine the machine, The frame, Compressor in, Parts mounted position check method and criterion

Advertising
background image

6.1 TROUBLE CRITERION OF MAIN PARTS

MR-385R-A

MR-420R-A

MR-455R-A

MR-385R-A(NZ)

MR-420R-A(NZ) MR-455R-A(NZ)

Compressor

Measure the resistance with a tester.

(Ambient temperature:Room temperature 15

o

C ~ 25

o

C)

In the control

panel of the

Measure the resistance with a tester.

refrigerator

compartment

Model

Measure the resistance with a tester.(Ambient temperature:Room temperature 15

o

C ~ 25

o

C)

PTC RELAY

PTH7M330MD2

Measure the resistance with a tester.

(Ambient temperature:Room temperature 15

o

C ~ 25

o

C)

Normal

abnormal(faulty)

As PTC Relay has been heated while refrigerator is running be sure
to measure the resistance after the thermistor has got cool enough.

6 TROUBLE SHOOTING

69 + 9

o

C

120 + 5

o

C

400VAC

Run capacitor

Opened (

∞Ω )

W

Rated input

Compressor in

Opened (∞Ω )

69 + 9

o

C

Motor

protector

120 + 5

o

C

- 14 -

33 Ω (Approx.)

Connected

Point

Model

Normal

abnormal(faulty)

Less than 1Ω

Opened (∞Ω ) or Short (0Ω)

rear side of
the frame

Starting current
Running current

A

chamber at the

Compressor in

the machine

chamber at the

rear side of

the machine

the machine

chamber at the

Components/

Part Name

Model

Parts Mounted

Position

Check Method and Criterion

DG57C96RAW5

MR-420R,455R

MR-385R

DG66C11RAW5

the frame

Compressor in

rear side of
the frame

Abnormal

(faulty)

Close

Open

Normal

Main wiring

Auxilliary wiring

17.7 Ω (Approx.)

5TM181NHBYY

5TM205NHBYY

abnormal(faulty)

A

Opened(∞ Ω )

RU

Short (0Ω)

7.38/8.01(220/240V 50Hz)

0.57/0.55(220/240V 50Hz)

Normal

MR-385R

MR-420R,455R

18.2 Ω (Approx.)

17.7 Ω (Approx.)

15.4 Ω (Approx.)

117/118(220/240V 50Hz)

8.05/8.83(220/240V 50Hz)

0.71/0.66(220/240V 50Hz)

106/108(220/240V 50Hz)

Short (

0Ω )

MR-420R,455R

MR-385R

Rated input

Auxilialy
wiring

Main
wiring

5

6

3

2

5

6

2

3

Advertising