2. Remove parts inside the refrigerator

(1) Remove chilled case door and slide chilled case ,

remove crystal shelf of refrigerator room , remove the
control panel
(Photo 6)

(2) Remove lamp cover R

(Photo 6)

(3) Remove screw and rivet , pull the control panel with

to right refrigerator wall.
(Photo 6)

(4) Pick the aluminium tape and sealing tape, remove

PC Board
(Photo 7)

(5) Remove duct R assy, damper thermo is installed

within it.
(Photo 7)
Remove the screw of damper thermo

Caution on assembly
1. Be sure to use new sealing materials and tape for
assembly.

- 21 -

OPERATION PROCEDURE

PHOTO

2. Attach the sealing material of refcon assy and attach
the aluminium tape everytimes for protective moisture.

Photo 6

Photo 7

Rivets

Thermo dial R

Lamp cover R

Screws

Control panel

Thermo dial F

Aluminium tape

Duct R assy

Sealing tape

PC Board