Measure the resistance with a tester – MITSUBISHI ELECTRIC MR-455R-W-A(NZ) User Manual

Page 16

Advertising
background image

Fan grill of the
freezer compartment.

Measure the resistance with a tester.

(Ambient temperature:Room temperature 15

o

C ~ 25

o

C)

In the drip tray under
the evaporator of the
freezer compartment

Measure the resistance with a tester.

(Ambient temperature:Room temperature 15

o

C ~ 25

o

C)

Resistance measured under

Defrost thermistors

the ambient temperature from

Thermistor resistance

radiator

-50: to +50:

(k

Ω)

against temperature

of the freezer
compartment.

1. 200" to 500k"

F-thermistor, control

............normal

panel of the refrigerator

2. Out of the above range

compartment.

............abnormal

Thermistor Check Procedure

Thermistor resistance will vary
with the change of temperature.

(

o

C)

Take the temperature around the thermistor,

Temperature

and then measure resistance using a tester.
The relation of resistance and temperature is as shown on the above graph.

- 15 -

Short (0Ω)

Rated input

150 W

operation method

Power ON after defrosting

(14 + 1.5

o

C or more)

10

Thermistor

30

Opened

( ∞ Ω

)

Defrost

Heater

Abnormal (faulty)

Normal

384

(Approx.)

-20 -10

0

20

abnormal(faulty)

Refrigerator

fan motor

560+ 10% ( Ω )

UDVH15MA1H

Model

Normal

Check Method and Criterion

Parts Mounted Position

Components/

Part Name

5

10

15

20

25

30

Resistance

Advertising