Cable and Gland Installation Notes










Step 1
: Make a cable as specified on
Page 10 or 11.
Plug in the RJ 45 into the ODU.










Step 2: Support the drop cable and gently
hand screw the gland body into the ODU
until the O ring seal is flush to the ODU
body.

Caution

Do not fit the back shell prior to

securing the gland body.







Step 3
: Once the gland is fully hand
screwed into the ODU it may be tight-
ened to a torque of to 7 ftlbs/10Nm,
with a 22mm wrench.








Step 4
:When the gland body has been
fitted, tighten the gland back shell.


Attention

Do not over tighten the gland

back shell









Gland on the right-hand side has been
over tightened. As a result, the internal
seal and structure have been damaged.

Should it be necessary to disconnect the
cable at the ODU (or PTP LPU), this can be
achieved by removing the gland back shell
first. Then, wiggle the cable to release the
tension of the gland body as shown in the
figure below. Then you can unscrew the
gland body and depress the RJ45 locking
tab with a small screwdriver.

12

Apply small movements to the cable until
you see a gap here before unscrewing the
gland body.