Bench testing (optional) - configuration checks – Motorola PTP 500 User Manual

Page 6

Advertising
background image

6

Step 13: Access the ‘Installation
Wizard’, ’Wireless Configuration’
page . Confirm the target MAC Ad-
dress, Master Slave Mode and other
configuration choices. Reboot the
unit.

If testing connectorized ODUs, con-
nect them together.

Repeat steps 1-13 for the paired unit
and check that the status of the link
shows UP on the ‘Status Page’.

Step 11: You may wish to upgrade the software. If so, select ‘Software Upgrade’ and follow
the on-screen instruction. Latest software is available from our web site:

(http://motorola.motowi4solutions.com/software/#ptp)

Bench Testing (Optional) - Configuration Checks

Step 12: Check the License Key informa-
tion and ensure you are using the correct
Region Code. Otherwise, select ‘License
Key’ and replace with the alternative key
supplied and reboot the unit.

Step 10: Use a web browser to connect to IP
address

http://169.254.1.1

for Slave and

http://169.254.1.2

for Master units. Select

‘System Administration’ and ‘Login’. (The
password will be empty for new units). We
recommend that you change the password by
selecting ‘Change Password’ in the Menu
bar.

Advertising