D7.3L D-TRONIC DIESEL ENGINES - BRAVO MODELS

Page 37 of 90

Drive Unit Seawater Routing

Seawater for engine cooling is supplied through a separate seawater pickup, not through

the drive unit. Therefore, it is necessary to block the drive unit seawater passage and to cut

the water hose that is located between the bell housing and the gimbal housing. This allows

water to continue to circulate through the drive unit for cooling.

BLOCK-OFF PLATE

1. Install block-off plate with gasket. Torque screws with star washers to 45 lb-in. (5 Nm).

75313

c

a

b

75314

a

b

c

a -

Plate

b -

Gasket

c -

Screw And Washer

CAUTION

Avoid drive unit damage. Quick release button on gear lube monitor

90

°

hose fitting

may not lock on gimbal housing if touching or depressed by block-off plate. Ensure
quick release button does not contact block-off plate. Failure to do so could result
in a loose

90

°

fitting causing a loss of gear lube and damage to drive unit.

2. Position quick release button on hose fitting away from block-off plate. Release button

must not contact block-off plate.

71998

d

OK

b

d

a

c

a -

Water Inlet Fitting

b -

Star Washer and Screw

c -

90

°

Hose Fitting

d -

Quick Release Button