OM-1589 Page 13

3-4.

Rear Panel Connections

Ref. 800 689

1

Rating Label Location

2

Coolant Supply Hose

Route supply hose and connect to
rear of Water To Gun fitting in
feeder.

3

Weld Cable

If using conventional welding power
source, route through reed relay in
feeder. Connect to power block.

4

Coolant Return Hose

Route return hose and connect to
rear of Weld/Water From Gun fitting
or optional flow switch in feeder.

5

Gas Hose

6

14-Pin Plug

Tools Needed:

9/16, 5/8, 11/16 in

6

5

2

3

4

1

3-5.

14-Pin Plug Information

Pin*

Pin Information

A

24 volts ac with respect to socket G.

A

J

B

Contact closure to A completes 24 volts ac contactor control circuit.

A

J

B

K

I

G

Circuit common for 24 volts AC circuit.

B

K

I

C

L

N

H

D

Remote control circuit common.

C

L

N

H

D

M

G

E

F

E

0 to +10 volts dc input command signal from remote control with respect to socket D.

D

M

G

E

F

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

M

CC/CV Select (+24 V = CV)

N

Inductance (0-10 V)

*The remaining pins are not used.