1. selecting dual schedule pair – Miller Electric OM-1589 User Manual

Page 30

Advertising
background image

OM-1589 Page 24

SECTION 6 − SETTING DUAL SCHEDULE PARAMETERS

6-1.

Selecting Dual Schedule Pair

Dual Schedule is used with two
consecutive weld programs 1 & 2,
3 & 4, 5 & 6, or 7 & 8. Any program
type (MIG, Adaptive Pulse, or
Pulse) can be combined in dual
schedule.

1

Side Panel Display

Use side panel to turn feature on.
See Menu Guide for detailed pro-
gramming steps.

2

Front Panel Display

Press front panel parameter select
button to select program number.

3

Front Panel Display Control

4

Inc/Dec Switch Used As Dual
Schedule Switch

5

Welding Gun Trigger

.

Switch type is set in System
Setup (see Section 6-2
).

Selecting dual schedule program A
or B is done by using Display Con-
trol, dual schedule switch, or gun
trigger (depending on system set-
up).

When program B is active, turn
Display Control one click clockwise
to select another pair of dual sched-
ule programs.

.

Programs can be rearranged in
desired order using the data
card. See Menu Guide for de-
tailed programming steps.

When dual schedule is On, and Process is selected on the
side panel display, then the side panel increase/decrease but-
tons can be used to change program numbers.

P r o c e s s
S e q u e n c e

> D u a l S chd

C a r d

> P r g

1 & 2

O n

2

2 4 . 0 V

2 5 0

I P M

> P r g

1

D u a l

A

> P r g

2

D u a l

B

> P r g

3

D u a l

A

3

Or

Display
Control

Display
Control

1

4

5

Advertising