OM-1589 Page 15

3-8.

Front Panel Connections for Gun

Ref. 800 688-B

Tools Needed:

5/8, 11/16, 1-1/8 in

Water-Cooled Guns:

1

Gun Control Cable

Insert plug into Gun Control receptacle, and
tighten threaded collar.

2

Gas Hose

Connect to Gas fitting on feeder.

3

Power/Water Cable

4

Strain Relief

Remove strain relief as shown.

Route cable through strain relief and connect

to Weld/Water From Gun outlet on feeder (left-
hand threads). Reinstall strain relief.
5

Wire Conduit

Route through strain relief. Insert through
front panel. Go to Section 3-6.
6

Water Hose

Connect to Water To Gun fitting on feeder (left-
hand threads).

Air-Cooled Gun:
7

Gun Control Cable

Insert plug into Gun Control receptacle, and
tighten threaded collar.

8

Gas Hose

Connect to Gas fitting on feeder.

9

Power Cable

Route cable through front panel and connect
to power block. See Section 3-7.

10 Strain Relief

Remove strain relief as shown.

11 Wire Conduit

Route through strain relief. Insert through
front panel. Go to Section 3-7.

6

5

4

1

3

2

Water-Cooled