4. troubleshooting check table – MITSUBISHI ELECTRIC Mitsubishi Split-Type User Manual

Page 15

Advertising
background image

15

NOTE : When the indoor unit has started operation and the above detection method has detected an abnormality (the first

detection after the power ON), the indoor electronic control P.C. board turns OFF the indoor fan motor with
OPERATION INDICATOR lamp flashing.

No.

1

3

6

7

Symptom

Operation indicator lamp

Detection method

Check point

Left lamp flashes.
0.5-second ON

0.5-second OFF

Mis-Wiring
or serial
signal

Outdoor
power
system

Outdoor
thermistors

Outdoor
control
system

Indoor coil
thermistor

When the serial signal from the outdoor unit is
not received for a maximum of 6 minutes.

When it consecutively occurs 3 times that the
compressor stops for overcurrent protection or
start-up failure protection within 1 minute after
start-up.

When the outdoor thermistors short or open
circuit during the compressor operation.

When it cannot properly read data in the
nonvolatile memory of the inverter P.C. board
or the outdoor electronic control P.C. board.

• Refer to "Check of outdoor

thermistor".

Refer to service manual
OB379 or OB377.

• Refer to "Check of inverter/

compressor".

Refer to service manual
OB379 or OB377.
Check the stop valve.

• Replace the inverter P.C.

board or the outdoor

electronic control P.C. board.

Refer to service manual

OB379 or OB377.

• Refer to 9-6.

D

"How to check

mis-wiring and serial signal

error".

4

Indoor fan
motor

8

Abnormal

point

Room
tempera-
ture
thermistor

Left lamp flashes.
2-time flash

2.5-second OFF

When the indoor coil or the room temperature
thermistor is shorts or opens circuit.

• Refer to 9-7.the
characteristics of indoor coil
thermistor, and the room
temperature thermistor.

Left lamp flashes.
3-time flash

2.5-second OFF

When the rotational frequency feedback
signal is not emitted during the indoor fan
operation.

• Refer to 9-6.

A

"Check of

indoor fan motor".

Indoor unit
and outdoor
unit do not
operate.

Indoor unit
and outdoor
unit do not
operate.

Left lamp flashes.
5-time flash

2.5-second OFF

Left lamp flashes.
6-time flash

2.5-second OFF

Indoor unit
and outdoor
unit do not
operate.

Indoor unit
and outdoor
unit do not
operate.

Indoor unit
and outdoor
unit do not
operate.

Other
abnormality

An abnormality other than above mentioned is
detected.

• Confirm the abnormality in
detail using the failure mode
recall function.

Indoor unit
and outdoor
unit do not
operate.

Indoor unit
and outdoor
unit do not
operate.

9

5

Left lamp flashes.
4-time flash

2.5-second OFF

Indoor
control
system

When it cannot properly read data in the
nonvolatile memory of the indoor electronic
control P.C. board.

Indoor unit
and outdoor
unit do not
operate.

• Replace the indoor electronic

control P.C. board.

Outdoor
control
system

When it cannot properly read data in the
nonvolatile memory of the inverter P.C. board
or the outdoor electronic control P.C. board.

• Check the blinking pattern of
the LED on the inverter P.C.
board or the outdoor
electronic
control P.C. board.

2

Outdoor unit
does not
operate.

Left lamp lights up

Left lamp flashes.
7-time flash

2.5-second OFF

Left lamp flashes.
14-time flash

2.5-second OFF

9-4. Troubleshooting check table

NOTE : Before taking measures, make sure that the symptom reappears for accurate troubleshooting.

Self check table

Not lighted

Blinking

OPERATION INDICATOR

Lighted

· Flashing of OPERATION INDICATOR lamp (left-hand side lamp)

indicates abnormalities.

OB378_--1qxp 05.1.17 12:55 Page 15

Advertising
This manual is related to the following products: